Introducing Heating Solutions Programmable thermostat for underfloor heating

Programmable thermostats are used with underfloor heating systems for energy savings. With programmable thermostats, you are able to control the temperature(s) and the times(s) at which each individual room is heated. Bedroom areas and living areas can be therefore be set to come on at different times and temperatures (6 different on/off times daily). For example, you can keep bedroom at a setback temperature during the day and have it increased to 18 degrees for an hour or two in the evening. Multiply this by the amount of bedrooms you have and you have saved already multiple Kw's of energy.

Our Programmable thermostat has the following functions.
Battery Low Indicator.(TH-9520B)
5+2D Programmable Blocks
6/4 Periods
Programming Resolution: 10 Minutes
Physical dimensions: 70 x 70 x 50 mm
Display range: 0° C – 37° C
Control range: 5° C – 35° C
Temperature display: Celsius
Electrical load limit: 250 V/ 5 A, 50-60 Hz Sampling
resolution 1 minute interval
Time display: 24 hours
Optional programming Periods:
Monday – Friday: 6 periods per day
Saturday: 4 periods per day
Sunday : 4 periods per day
Temperature differential Preset = 1°C, 0,5°C above 0,5°
Temperature adjustment 1°C

Proper location of this thermostat is very important to ensure
a comfortable temperature. Observe the following general
rules for best results.
1. The thermostat should be on the inside wall of a room
that is often used, approx. 5 ft (1.5m) above the floor.
2. Avoid areas that exhibit unusual heating or cooling
conditions such as in direct sunlight, near a fireplace,
stove register, door, window or stair well.
3. Be aware of furnishings, which may block airflow, or
alter temperature such as sofas, chairs, bookcases, track
lighting, lamps, stereo components and television sets.
4. Hot water pipes in the wall, a stove, refrigerator, or
fireplace on the other side of a prospective wall may
affect the accuracy of your thermostat.
5. Locating any control in a damp area will cause corrosion,
and shorten the life of the control.
6. Do not install where air circulation is poor (i.e. In a
corner, or an alcove, or behind an open door).
7. All construction work and painting should be complete
before installing unit.
8. This thermostat does not require leveling.